Generator inertia
1 Test description
This test checks the Generator inertia parameter of the RNA. The rotor of the NREL 5-MW wind turbine spins in air of zero density, so that there are no aerodynamic loads, and is braked by a generator that applies a constant torque. The rotor speed then falls at a constant rate, which depends only on the torque and on the rotating inertia of the drivetrain: the rotor and, when it is given, the generator.
The test compares the rotor speed, the generator speed and the torque in the main shaft with the analytical solution in the following load cases:
- Stiff rotor no generator inertia
- Stiff rotor
- Stiff rotor direct drive
- Flexible rotor no generator inertia
- Flexible rotor
2 Model
The model is the RNA only template, with the rotor of the NREL 5-MW wind turbine. The generator is of the type Fixed torque. The air density is 0, the load ramp-up is switched off, so that the generator torque is applied in full from the first time step, and the main shaft has the material InfStiffMassless, so that the rotor and the generator turn as one body. Each load case lasts 20 s.
| Load case | Rotor model | Gear ratio | Generator torque (Nm) | Generator inertia (kgm2) |
|---|---|---|---|---|
| Stiff rotor no generator inertia | Stiff | 97 | 10 000 | 0 |
| Stiff rotor | Stiff | 97 | 10 000 | 534.116 |
| Stiff rotor direct drive | Stiff | 1 (direct drive) | 970 000 | 5 025 497.444 |
| Flexible rotor no generator inertia | Flexible | 97 | 10 000 | 0 |
| Flexible rotor | Flexible | 97 | 10 000 | 534.116 |
The gear ratio of 97 and the generator inertia of 534.116 kgm2 are those of the NREL 5-MW wind turbine. The direct-drive load case has the same torque and the same inertia on the main shaft as the geared one, and must give the same results.
3 Analytical solution
This gives the following values:
| Load case | Rotor speed after 20 s (rpm) | Torque on main shaft (kNm) |
|---|---|---|
| Stiff rotor no generator inertia | 7.259 | 970.0 |
| Stiff rotor | 7.821 | 857.4 |
| Stiff rotor direct drive | 7.821 | 857.4 |
| Flexible rotor no generator inertia | 7.254 | not compared |
| Flexible rotor | 7.817 | not compared |
4 Results
With the stiff rotor, the rotor speed (RPM of the Rotor sensor) and the generator speed (RPM of the Generator sensor) are compared over the whole time series, and the generator Torque and the Torque on main shaft over the last fifth of it. The test is considered passed if the results from Ashes lie within 0.2 % of the analytical solution.
With the flexible rotor, the torque step also sets the blades vibrating edgewise, and the speed that the sensors give is that of the hub. The torque in the main shaft follows this vibration and is not compared, and the two speeds are compared at the end of the simulation only. The flexible rotor also slows down slightly faster than the inertia in its part information gives, with or without generator inertia, which leaves the speed at the end about 1.5 % below the analytical solution. The test is considered passed if the two speeds lie within 3 % of it. Leaving the generator inertia out changes the speed at the end by 7 %, so these two load cases show that the inertia is there with flexible blades; its value is checked by the load cases with the stiff rotor.
The report for this test can be found on the following link: